UDTR Global Radar

UDTR Global Rights of Nature Radar

Documentary registry of records detected across the scholarly, legal and institutional infrastructures monitored by UDTR.

A global documentary infrastructure designed to achieve the broadest verifiable and scientifically defensible coverage of the Rights of Nature.

← Back to Radar

Towards an automated dislocation density measurement in the SEM : Benefits and limits of the R-ECCI method

Identification

Public canonical key
radar:r-d9fb29bd943a442c8c7bc6389ddf1992
Authors
Julien Gallet
Reported year
—
Reported language
en
Source type
THESE
First detected
2026-11-13T15:28:35.891468+00:00
Last metadata observation
2026-11-13T15:28:35.891468+00:00
Last HTTP verification
Not checked

Institutions reported by the source

Matériaux, ingénierie et science [Villeurbanne] · Université Claude Bernard Lyon 1 · Université de Lyon · Institut National des Sciences Appliquées de Lyon · Institut National des Sciences Appliquées · Centre National de la Recherche Scientifique

Documentary abstract — original language

In order to predict the mechanical behavior of metallic materials, it is important to determine several physical quantities, including the dislocation density which has a major impact on mechanical properties. Recent work has shown that it is possible to make these observations using a Scanning Electron Microscope. Indeed, this method has the advantage of being applied on bulk samples and of allowing the observation of larger areas. However, a sample orientation step is necessary, and the image processing is done manually. This makes the approach long and tedious. The R-ECCI method is based on the acquisition of a series of images at different rotation angles and allows to avoid the sample orientation step. An intensity profile is obtained, which is representative of the nature of the considered pixel (dislocation, defect or matrix). The objective of this thesis project was to develop a method of automatic characterization of the dislocation density, using a clustering type algorithm applied on the profiles. The images are processed in an automated way and the dislocation density is calculated. The first part of the project focused on the development of the image acquisition methodology and the data processing software and allowed to determine the limits and the strengths of the method. In a second part, a quantitative comparison with existing measurement methods (TEM, DRX, HR EBSD ...) was performed. In addition to the fact that each of these methods does not detect the same populations of dislocations, complementary results in terms of limits of detectability have been obtained. Finally, results obtained on a known alloy were compared to those obtained by a micro-mechanical prediction model, and a good compromise was found, which allows to validate the global approach of R-ECCI.

Identifiers

DOI
10.70675/def98f84zeed3z4aacz8abdz55039f5acf5d
HAL
tel-04220639

Documentary context

Documentary family
Thesis
Source-reported types
THESE

Entity mentions are not evidence of legal recognition. Jurisdiction studied is separate from author affiliation country.

Sources

HAL · Record 1

Cite this reference

Julien Gallet. Towards an automated dislocation density measurement in the SEM : Benefits and limits of the R-ECCI method. https://doi.org/10.70675/def98f84zeed3z4aacz8abdz55039f5acf5d

JSON · CSL-JSON · BibTeX · RIS · CSV · JSON-LD ·

APA, Chicago, ISO 690: bibliographic formats using available fields. OSCOLA / Bluebook: structured data only; full legal citation compliance is not claimed without verification of required elements.

APA
Julien Gallet. Towards an automated dislocation density measurement in the SEM : Benefits and limits of the R-ECCI method. https://doi.org/10.70675/def98f84zeed3z4aacz8abdz55039f5acf5d
Chicago
Julien Gallet. Towards an automated dislocation density measurement in the SEM : Benefits and limits of the R-ECCI method. https://doi.org/10.70675/def98f84zeed3z4aacz8abdz55039f5acf5d
ISO 690
Julien Gallet. Towards an automated dislocation density measurement in the SEM : Benefits and limits of the R-ECCI method. https://doi.org/10.70675/def98f84zeed3z4aacz8abdz55039f5acf5d

Warning: Undefined array key "last_link_verified" in /home/clients/e27d81e12f04d2bfd747aa264540ac56/sites/_UDTR_APP/legal_library_reference.php on line 31

UDTR Global Rights of Nature Legal Library. Towards an automated dislocation density measurement in the SEM : Benefits and limits of the R-ECCI method. Documentary record: https://www.declarationuniverselledesdroitsdelarbre.org/global-rights-of-nature-radar/reference/r-d9fb29bd943a442c8c7bc6389ddf1992/ · Last HTTP verification: not performed

Report a correction

Frozen-version metadata

Research dossiers and documentary relations

Source roles

Bibliographic / original publication source · https://theses.hal.science/tel-04220639v1

An authority link alone does not verify a legal claim. Abstracts and full texts remain subject to their source terms.

Documentary status

Relevance pending

Library

This identity is not yet included in the Legal Library.

UDTR Global Rights of Nature Legal Library