Portuguese Rural Fire Database - PRDF (1980-2025)
Identification
- Public canonical key
- radar:r-8c212b6ca39d64031531e5c8caf78c0e
- Authors
- Lopes Almeida, Rui · Cerasoli, Sofia · Pacheco Pereira, Abílio
- Reported year
- 2026
- Reported language
- en
- Source type
- Dataset
- First detected
- 2026-11-13T08:38:46.350120+00:00
- Last metadata observation
- 2026-11-13T08:38:46.350120+00:00
- Last HTTP verification
- Not checked
Institutions reported by the source
Instituto da Conservação da Natureza e das Florestas · Faculdade de Engenharia da Universidade do Porto · Forest Research Centre, TERRA Associate Laboratory · INESC TEC
Documentary abstract — original language
Portuguese Rural Fire Database (PRFD), 1980–2025 The Portuguese Rural Fire Database (PRFD) is the official record of rural fires in mainland Portugal kept by the Institute for Nature Conservation and Forests (ICNF). This version provides a continuous 46-year series (1980–2025) of 824,488 fire records. Five historical data structures are harmonized into a single, traceable dataset, enriched with information from multiple sources and assessed for quality record by record. Records from 2001 onwards have field coordinates; records from 1980–2000 have no coordinates and are placed at their toponym, with an estimated location uncertainty (median radius 9.5 km). Original values are always kept; corrected and imputed values are stored in separate fields and flagged. The dataset consists of a core event table and linked files, all joined by the fire code Codigo: FOGOS: one row per fire event (date, time, location, cause, burned area, duration). Each record also carries variables added from external sources: hourly ERA5 weather and the Fire Weather Index at ignition; topography, solar exposure, land use and fuel model; pre-fire MODIS vegetation state; Fire Radiative Energy and burn severity; population, building and road density; the nearest fire station and simultaneous fires. METEO: hourly meteorological records (temperature, relative humidity, wind speed and direction, precipitation) and the Fire Weather Index and its sub-indices for each fire event. PBA: annual burned-area perimeters mapped from satellite imagery, 1975–2025. FRP: SEVIRI Fire Radiative Power observations for mainland Portugal, 2004–2024, with the fire each hotspot was assigned to. FOGOS_anexo: auxiliary fields for each event: timestamp-correction rules, imputation flags and intervals, severity areas by class, age of the MODIS composites, and the record-level quality indicators and tier. FOGOS_audit: record-level quality assessment. It covers the location uncertainty of the ignition point, the agreement between the reported and the perimeter area, the imputation level, and independent confirmation by a burned-area perimeter and SEVIRI FRP hotspots. It also includes the confidence of the perimeter link and an overall quality tier (A Gold, B Silver, U Unverifiable, C Caution). Formats. The tables are provided in CSV, each with a data dictionary (variable, description, unit, source, information category). PRFD.gpkg contains the ignition points, the linked perimeters, the annex, the audit table and the data dictionaries. Coordinates are in EPSG:3763 (ETRS89 / PT-TM06). Code. The R code used to build the dataset is available at https://github.com/ralmeida2010/RSGIF. Updated raw records are published by ICNF at https://fogos.icnf.pt/download/ExportarDadosSGIF/. New Version. This version keeps the 1980–2025 record and its harmonized core fields, and changes mainly in three groups of variables. The first is environmental and fire-effect information: The MODIS-based severity (SeverusPT) is replaced by the longer Landsat series of the Portuguese Burn Severity Atlas (1984–2022). Its five dNBR classes sit alongside the EFFIS Sentinel-2 classes (2018–2025). The pre-fire vegetation state at the ignition point is described with MODIS GPP (8-day and accumulated since 1 January, as dry matter), FAPAR, LAI, NDVI, EVI and NDII7, each with the age of the composite used. Fire Radiative Energy is now reported in GJ (FRE_GJ), together with the number of SEVIRI hotspots and the phase in which each fire’s energy was computed (perimeter or ignition point). The derived spread rate is replaced by burned area per hour (HaHora and HaHoraEstimado). The second group is record-level quality. Each record now carries: an uncertainty radius for its location (R95), calibrated by municipality and toponym type; a spatial precision class; the agreement between the reported and the perimeter area; an imputation level; a count of independent confirmations (PBA perimeter and SEVIRI FRP only); a low-confidence flag for the perimeter link; a quality tier, which now has four classes, adding Tier U for unverifiable records to A, B and C. The third group documents corrections and imputation in a separate annex (FOGOS_anexo) and an audit table (Fogos_audit): the timestamp-correction rule applied to each record; flags for imputed and anomalous values; the 5th–95th percentile interval of the imputed areas and durations; the original reported values, kept unchanged next to the estimated ones. Each table also has a data dictionary.
Identifiers
- DOI
- 10.5281/zenodo.21427771
Documentary context
- Documentary family
- dataset
- Source-reported types
- Dataset
- Publishers
- Zenodo
Entity mentions are not evidence of legal recognition. Jurisdiction studied is separate from author affiliation country.
Sources
DataCite · Record 1
Cite this reference
Lopes Almeida, Rui; Cerasoli, Sofia; Pacheco Pereira, Abílio. Portuguese Rural Fire Database - PRDF (1980-2025). 2026. https://doi.org/10.5281/zenodo.21427771
JSON · CSL-JSON · BibTeX · RIS · CSV · JSON-LD ·
APA, Chicago, ISO 690: bibliographic formats using available fields. OSCOLA / Bluebook: structured data only; full legal citation compliance is not claimed without verification of required elements.
- APA
- Lopes Almeida, Rui; Cerasoli, Sofia; Pacheco Pereira, Abílio. (2026). Portuguese Rural Fire Database - PRDF (1980-2025). https://doi.org/10.5281/zenodo.21427771
- Chicago
- Lopes Almeida, Rui; Cerasoli, Sofia; Pacheco Pereira, Abílio. Portuguese Rural Fire Database - PRDF (1980-2025). 2026. https://doi.org/10.5281/zenodo.21427771
- ISO 690
- Lopes Almeida, Rui; Cerasoli, Sofia; Pacheco Pereira, Abílio. Portuguese Rural Fire Database - PRDF (1980-2025). 2026. https://doi.org/10.5281/zenodo.21427771
Warning: Undefined array key "last_link_verified" in /home/clients/e27d81e12f04d2bfd747aa264540ac56/sites/_UDTR_APP/legal_library_reference.php on line 31
UDTR Global Rights of Nature Legal Library. Portuguese Rural Fire Database - PRDF (1980-2025). Documentary record: https://www.declarationuniverselledesdroitsdelarbre.org/global-rights-of-nature-radar/reference/r-8c212b6ca39d64031531e5c8caf78c0e/ · Last HTTP verification: not performed
Research dossiers and documentary relations
Source roles
Bibliographic / original publication source · https://zenodo.org/doi/10.5281/zenodo.21427771
An authority link alone does not verify a legal claim. Abstracts and full texts remain subject to their source terms.
Documentary status
Relevance pending
Library
This identity is not yet included in the Legal Library.