The design of ECG preamplifier for wearable device
Identification
- Public canonical key
- radar:r-4d854639ec8feaf3754d8eceaf3e155d
- Authors
- Longrui Han · Xinyu Li · Zewen Yang
- Reported year
- —
- Reported language
- Undetermined
- Source type
- publication
- First detected
- 2026-11-13T15:33:50.487214+00:00
- Last metadata observation
- 2026-11-13T15:33:50.487214+00:00
- Last HTTP verification
- Not checked
Documentary abstract — original language
Electrocardiogram (ECG) has been more and more widely used over the past several decades. However, the commonly used ECG instrument has the disadvantages of large area occupation and heavy. Due to the strong sudden nature of heart disease, and the traditional electrocardiotic monitoring system has cumbersome operation and poor real-time electrocardiograms. Ordinary people cannot read the electrocardiogram correctly, and cannot meet the needs of individual and family electrocardiological supervision at any time and anywhere. Patients often lose valuable rescue time and even lose their lives because they cannot monitor ECG in time. Therefore, the design of a wireless ECG guardianship system is of great significance to home and personal electrocardiotic guardianship. In order to solve these limitations, a wearable ECG circuit was proposed here. The front part of the amplifier circuit was composed by the single-stage operation amplifier to minimize the number of electronic components. The wearable ECG was simulated by using Multisim simulation software to verify the feasibility of the design. The main reason for using Multisim is that it can well complete our simulation tasks in the experiment and its cost requirements are not very high. It can be experimented anytime, anywhere, without device damage and personal risk, so we chose Multisim to do the initial experiment, and conduct further experiments after the experimental results are feasible
Identifiers
- DOI
- 10.1109/icmsp53480.2021.9513221
Documentary context
- Documentary family
- unknown
- Source-reported types
- publication
- Publishers
- IEEE
Entity mentions are not evidence of legal recognition. Jurisdiction studied is separate from author affiliation country.
Sources
OpenAIRE · Record 1
Cite this reference
Longrui Han; Xinyu Li; Zewen Yang. The design of ECG preamplifier for wearable device. https://doi.org/10.1109/icmsp53480.2021.9513221
JSON · CSL-JSON · BibTeX · RIS · CSV · JSON-LD ·
APA, Chicago, ISO 690: bibliographic formats using available fields. OSCOLA / Bluebook: structured data only; full legal citation compliance is not claimed without verification of required elements.
- APA
- Longrui Han; Xinyu Li; Zewen Yang. The design of ECG preamplifier for wearable device. https://doi.org/10.1109/icmsp53480.2021.9513221
- Chicago
- Longrui Han; Xinyu Li; Zewen Yang. The design of ECG preamplifier for wearable device. https://doi.org/10.1109/icmsp53480.2021.9513221
- ISO 690
- Longrui Han; Xinyu Li; Zewen Yang. The design of ECG preamplifier for wearable device. https://doi.org/10.1109/icmsp53480.2021.9513221
Warning: Undefined array key "last_link_verified" in /home/clients/e27d81e12f04d2bfd747aa264540ac56/sites/_UDTR_APP/legal_library_reference.php on line 31
UDTR Global Rights of Nature Legal Library. The design of ECG preamplifier for wearable device. Documentary record: https://www.declarationuniverselledesdroitsdelarbre.org/global-rights-of-nature-radar/reference/r-4d854639ec8feaf3754d8eceaf3e155d/ · Last HTTP verification: not performed
Research dossiers and documentary relations
Source roles
Bibliographic / original publication source · https://doi.org/10.1109/icmsp53480.2021.9513221
An authority link alone does not verify a legal claim. Abstracts and full texts remain subject to their source terms.
Documentary status
Relevance pending
Library
This identity is not yet included in the Legal Library.