Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands
Identification
- Public canonical key
- radar:r-30d15f973f086718db9657d769ef118d
- Authors
- A. Morvannou · S. Troesch · D. Esser · N. Forquet · Anne Petitjean · Pascal Molle
- Reported year
- —
- Reported language
- en
- Source type
- ART
- First detected
- 2026-11-13T08:38:54.312394+00:00
- Last metadata observation
- 2026-11-13T08:38:54.312394+00:00
- Last HTTP verification
- Not checked
Institutions reported by the source
EPUR NATURE CAUMONT SUR DURANCE FRA · Partenaires IRSTEA · Institut national de recherche en sciences et technologies pour l'environnement et l'agriculture · Milieux aquatiques, écologie et pollutions · SINT LA CHAPELLE DU MONT DU CHAT FRA
Documentary abstract — original language
French vertical flow constructed wetlands (VFCW) treating raw wastewater have been developed successfully over the last 30 years. Nevertheless, the two-stage VFCWs require a total filtration area of 2–2.5m2/P.E. Therefore, implementing a one-stage system in which treatment performances reach standard requirements is of interest. Biho-Filter® is one of the solutions developed in France by Epur Nature. Biho-Filter® is a vertical flow system with an unsaturated layer at the top and a saturated layer at the bottom. The aim of this study wasto assess this new configuration and to optimize its design and operating conditions. The hydraulic functioning and pollutant removal efficiency of three different Biho- Filter® plants commissioned between 2011 and 2012 were studied. Outlet concentrations of the most efficient Biho-Filter® configuration are 70 mg/L, 15 mg/L, 15 mg/L and 25 mg/L for chemical oxygen demand (COD), 5-day biological oxygen demand (BOD5), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN), respectively. Up to 60% of total nitrogen is removed. Nitrification efficiency is mainly influenced by the height of the unsaturated zone and the recirculation rate. The optimum recirculation rate was found to be 100%. Denitrification in the saturated zone works at best with an influent COD/ NO3-N ratio at the inflet of this zone larger than 2 and a hydraulic retention time longer than 0.75 days.
Identifiers
- DOI
- 10.2166/wst.2017.115
- HAL
- hal-02606812
Documentary context
- Documentary family
- article
- Source-reported types
- ART
Entity mentions are not evidence of legal recognition. Jurisdiction studied is separate from author affiliation country.
Sources
HAL · Record 1
Cite this reference
A. Morvannou; S. Troesch; D. Esser; N. Forquet; Anne Petitjean; Pascal Molle. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. https://doi.org/10.2166/wst.2017.115
JSON · CSL-JSON · BibTeX · RIS · CSV · JSON-LD ·
APA, Chicago, ISO 690: bibliographic formats using available fields. OSCOLA / Bluebook: structured data only; full legal citation compliance is not claimed without verification of required elements.
- APA
- A. Morvannou; S. Troesch; D. Esser; N. Forquet; Anne Petitjean; Pascal Molle. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. https://doi.org/10.2166/wst.2017.115
- Chicago
- A. Morvannou; S. Troesch; D. Esser; N. Forquet; Anne Petitjean; Pascal Molle. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. https://doi.org/10.2166/wst.2017.115
- ISO 690
- A. Morvannou; S. Troesch; D. Esser; N. Forquet; Anne Petitjean; Pascal Molle. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. https://doi.org/10.2166/wst.2017.115
Warning: Undefined array key "last_link_verified" in /home/clients/e27d81e12f04d2bfd747aa264540ac56/sites/_UDTR_APP/legal_library_reference.php on line 31
UDTR Global Rights of Nature Legal Library. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. Documentary record: https://www.declarationuniverselledesdroitsdelarbre.org/global-rights-of-nature-radar/reference/r-30d15f973f086718db9657d769ef118d/ · Last HTTP verification: not performed
Research dossiers and documentary relations
Source roles
Bibliographic / original publication source · https://hal.inrae.fr/hal-02606812v1
An authority link alone does not verify a legal claim. Abstracts and full texts remain subject to their source terms.
Documentary status
Relevance pending
Library
This identity is not yet included in the Legal Library.