UDTR Global Radar

UDTR Global Rights of Nature Radar

Documentary registry of records detected across the scholarly, legal and institutional infrastructures monitored by UDTR.

A global documentary infrastructure designed to achieve the broadest verifiable and scientifically defensible coverage of the Rights of Nature.

← Back to Radar

Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands

Identification

Public canonical key
radar:r-30d15f973f086718db9657d769ef118d
Authors
A. Morvannou · S. Troesch · D. Esser · N. Forquet · Anne Petitjean · Pascal Molle
Reported year
—
Reported language
en
Source type
ART
First detected
2026-11-13T08:38:54.312394+00:00
Last metadata observation
2026-11-13T08:38:54.312394+00:00
Last HTTP verification
Not checked

Institutions reported by the source

EPUR NATURE CAUMONT SUR DURANCE FRA · Partenaires IRSTEA · Institut national de recherche en sciences et technologies pour l'environnement et l'agriculture · Milieux aquatiques, écologie et pollutions · SINT LA CHAPELLE DU MONT DU CHAT FRA

Documentary abstract — original language

French vertical flow constructed wetlands (VFCW) treating raw wastewater have been developed successfully over the last 30 years. Nevertheless, the two-stage VFCWs require a total filtration area of 2–2.5m2/P.E. Therefore, implementing a one-stage system in which treatment performances reach standard requirements is of interest. Biho-Filter® is one of the solutions developed in France by Epur Nature. Biho-Filter® is a vertical flow system with an unsaturated layer at the top and a saturated layer at the bottom. The aim of this study wasto assess this new configuration and to optimize its design and operating conditions. The hydraulic functioning and pollutant removal efficiency of three different Biho- Filter® plants commissioned between 2011 and 2012 were studied. Outlet concentrations of the most efficient Biho-Filter® configuration are 70 mg/L, 15 mg/L, 15 mg/L and 25 mg/L for chemical oxygen demand (COD), 5-day biological oxygen demand (BOD5), total suspended solids (TSS) and total Kjeldahl nitrogen (TKN), respectively. Up to 60% of total nitrogen is removed. Nitrification efficiency is mainly influenced by the height of the unsaturated zone and the recirculation rate. The optimum recirculation rate was found to be 100%. Denitrification in the saturated zone works at best with an influent COD/ NO3-N ratio at the inflet of this zone larger than 2 and a hydraulic retention time longer than 0.75 days.

Identifiers

DOI
10.2166/wst.2017.115
HAL
hal-02606812

Documentary context

Documentary family
article
Source-reported types
ART

Entity mentions are not evidence of legal recognition. Jurisdiction studied is separate from author affiliation country.

Sources

HAL · Record 1

Cite this reference

A. Morvannou; S. Troesch; D. Esser; N. Forquet; Anne Petitjean; Pascal Molle. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. https://doi.org/10.2166/wst.2017.115

JSON · CSL-JSON · BibTeX · RIS · CSV · JSON-LD ·

APA, Chicago, ISO 690: bibliographic formats using available fields. OSCOLA / Bluebook: structured data only; full legal citation compliance is not claimed without verification of required elements.

APA
A. Morvannou; S. Troesch; D. Esser; N. Forquet; Anne Petitjean; Pascal Molle. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. https://doi.org/10.2166/wst.2017.115
Chicago
A. Morvannou; S. Troesch; D. Esser; N. Forquet; Anne Petitjean; Pascal Molle. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. https://doi.org/10.2166/wst.2017.115
ISO 690
A. Morvannou; S. Troesch; D. Esser; N. Forquet; Anne Petitjean; Pascal Molle. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. https://doi.org/10.2166/wst.2017.115

Warning: Undefined array key "last_link_verified" in /home/clients/e27d81e12f04d2bfd747aa264540ac56/sites/_UDTR_APP/legal_library_reference.php on line 31

UDTR Global Rights of Nature Legal Library. Using one filter stage of unsaturated/saturated vertical flow filters for nitrogen removal and footprint reduction of constructed wetlands. Documentary record: https://www.declarationuniverselledesdroitsdelarbre.org/global-rights-of-nature-radar/reference/r-30d15f973f086718db9657d769ef118d/ · Last HTTP verification: not performed

Report a correction

Frozen-version metadata

Research dossiers and documentary relations

Source roles

Bibliographic / original publication source · https://hal.inrae.fr/hal-02606812v1

An authority link alone does not verify a legal claim. Abstracts and full texts remain subject to their source terms.

Documentary status

Relevance pending

Library

This identity is not yet included in the Legal Library.

UDTR Global Rights of Nature Legal Library