UDTR Global Radar

UDTR Global Rights of Nature Radar

Documentary registry of records detected across the scholarly, legal and institutional infrastructures monitored by UDTR.

A global documentary infrastructure designed to achieve the broadest verifiable and scientifically defensible coverage of the Rights of Nature.

← Back to Radar

El-Rakhawi Continuous Hemodynamic Monitoring System (E-CHMS) v2.0: A Cuffless, Multi-Modal Blood Pressure and Arterial Stiffness Tracking Architecture Using Physics-Informed Neural Networks and Morphological Pulse Wave Analysis

Identification

Public canonical key
radar:r-193edf466483f4abecf375fd034c9c09
Authors
mohamed kamal arafa el-rakhawi
Reported year
2026
Reported language
en
Source type
book
First detected
2026-11-13T12:38:44.784626+00:00
Last metadata observation
2026-11-13T12:38:44.784626+00:00
Last HTTP verification
Not checked

Documentary abstract — original language

The El-Rakhawi Continuous Hemodynamic Monitoring System (E-CHMS) presents a breakthrough architecture for cuffless, continuous blood pressure monitoring, addressing the fundamental limitation of current PTT-based devices: their inability to distinguish between blood pressure changes and arterial stiffness variations. This ambiguity causes significant measurement drift, requiring frequent cuff recalibration. E-CHMS overcomes this through a tri-layer sensor fusion system: (1) Pulse Transit Time measurement via synchronized ECG and PPG signals; (2) Multi-Frequency Bio-impedance Plethysmography (50 kHz and 200 kHz) that independently quantifies arterial wall stiffness in real-time by measuring impedance ratios correlated with Young's modulus; (3) A Physics-Informed Neural Network (PINN) that integrates these modalities while embedding the Moens-Korteweg equation as a hard physical constraint, ensuring predictions remain physiologically plausible and preventing drift. The system decouples pressure from stiffness using the relationship: SBP(t) = α·(1/PTT²)·(1/Z_ratio) + β·T_skin + γ, where Z_ratio serves as a stiffness proxy. Grounded in established cardiovascular physics and utilizing commercially mature components (dry ECG electrodes, PPG sensors, bio-impedance AFE chips), E-CHMS provides a mathematically rigorous pathway toward truly calibration-free continuous monitoring with a design target of mean absolute error <5 mmHg per ISO 81060-2 standards. This architecture transforms cuffless blood pressure monitoring from speculative estimation into physics-compliant, clinically viable technology. DOI: 10.5281/zenodo.23099674

Identifiers

OPENALEX
https://openalex.org/W7216512187
DOI
10.5281/zenodo.23099673

Documentary context

Documentary family
Book
Source-reported types
book

Entity mentions are not evidence of legal recognition. Jurisdiction studied is separate from author affiliation country.

Book bibliographic description

Reported publication date
2026-10-02

Access status unknown

Sources

OpenAlex · Record 1

Cite this reference

mohamed kamal arafa el-rakhawi. El-Rakhawi Continuous Hemodynamic Monitoring System (E-CHMS) v2.0: A Cuffless, Multi-Modal Blood Pressure and Arterial Stiffness Tracking Architecture Using Physics-Informed Neural Networks and Morphological Pulse Wave Analysis. 2026. https://doi.org/10.5281/zenodo.23099673

JSON · CSL-JSON · BibTeX · RIS · CSV · JSON-LD ·

APA, Chicago, ISO 690: bibliographic formats using available fields. OSCOLA / Bluebook: structured data only; full legal citation compliance is not claimed without verification of required elements.

APA
mohamed kamal arafa el-rakhawi. (2026). El-Rakhawi Continuous Hemodynamic Monitoring System (E-CHMS) v2.0: A Cuffless, Multi-Modal Blood Pressure and Arterial Stiffness Tracking Architecture Using Physics-Informed Neural Networks and Morphological Pulse Wave Analysis. https://doi.org/10.5281/zenodo.23099673
Chicago
mohamed kamal arafa el-rakhawi. El-Rakhawi Continuous Hemodynamic Monitoring System (E-CHMS) v2.0: A Cuffless, Multi-Modal Blood Pressure and Arterial Stiffness Tracking Architecture Using Physics-Informed Neural Networks and Morphological Pulse Wave Analysis. 2026. https://doi.org/10.5281/zenodo.23099673
ISO 690
mohamed kamal arafa el-rakhawi. El-Rakhawi Continuous Hemodynamic Monitoring System (E-CHMS) v2.0: A Cuffless, Multi-Modal Blood Pressure and Arterial Stiffness Tracking Architecture Using Physics-Informed Neural Networks and Morphological Pulse Wave Analysis. 2026. https://doi.org/10.5281/zenodo.23099673

Warning: Undefined array key "last_link_verified" in /home/clients/e27d81e12f04d2bfd747aa264540ac56/sites/_UDTR_APP/legal_library_reference.php on line 31

UDTR Global Rights of Nature Legal Library. El-Rakhawi Continuous Hemodynamic Monitoring System (E-CHMS) v2.0: A Cuffless, Multi-Modal Blood Pressure and Arterial Stiffness Tracking Architecture Using Physics-Informed Neural Networks and Morphological Pulse Wave Analysis. Documentary record: https://www.declarationuniverselledesdroitsdelarbre.org/global-rights-of-nature-radar/reference/r-193edf466483f4abecf375fd034c9c09/ · Last HTTP verification: not performed

Report a correction

Frozen-version metadata

Research dossiers and documentary relations

Source roles

Bibliographic / original publication source · https://doi.org/10.5281/zenodo.23099673

An authority link alone does not verify a legal claim. Abstracts and full texts remain subject to their source terms.

Documentary status

Relevance pending

Library

This identity is not yet included in the Legal Library.

UDTR Global Rights of Nature Legal Library