Mechanical Stimulation in the Residual Femur During Gait in Transfemoral Prosthesis Users Provides a Potential Reason for Bone Mineral Density Loss
Identification
- Public canonical key
- doi:10.1002/cnm.70103
- Authors
- Jose L. Zavaleta‐Ruiz · Stefania Fatone · Matthew J. Major · Pankaj Pankaj
- Reported year
- 2025
- Reported language
- en
- Source type
- article
- First detected
- 2026-11-09T19:16:01.560938+00:00
- Last metadata observation
- 2026-11-09T19:16:01.560938+00:00
- Last HTTP verification
- Not checked
Institutions reported by the source
Jesse Brown VA Medical Center · Northwestern University · University of Edinburgh · University of Washington
Documentary abstract — original language
Individuals with transfemoral amputation (TFA) experience bone loss in their residual femur at levels seen in bedridden and post-menopausal individuals. It has been suggested that the time until first prosthesis fitting, gait deviations, and muscle atrophy may be contributing factors, but evidence is inconsistent. Prosthetic sockets are typically designed to off-load the distal end of the residual limb, yet the effect of the load transmission pathways of the prosthetic socket on a residual femur has not been examined. Using existing datasets, we recreated the prosthetic socket environment within finite element (FE) models by extracting the skeletal geometries of 10 able-bodied individuals from computer tomography scans, and anthropometrically pairing them with gait data acquired from individuals with unilateral TFA. Normal skeletal geometries were modified to resemble a TFA and fit with an ischial containment socket (ICS). The modified skeleton was positioned with respect to the socket using motion analysis marker locations and tested using the ground reaction forces corresponding to three gait instances from at least four steps. Additional mirror models without the ICS were created for comparison. We validated our study by comparing hip forces from the original gait data to acetabular contact forces estimated using the FE models. We found that the residual femur wearing an ICS experienced mean compressive strain of -105 ± 42 μE and -722 ± 155 μE without the ICS. Simulations show that this is because the ICS redirects load through the pelvis, diminishing force transmission from the femoral head to the acetabulum.
Identifiers
- OPENALEX
- W4415013930
- DOI
- 10.1002/cnm.70103
Documentary context
- Documentary family
- Scholarship
- Source-reported types
- article
Entity mentions are not evidence of legal recognition. Jurisdiction studied is separate from author affiliation country.
Sources
OpenAlex · Record 1 · Record 2
Documented bibliographic relations
Source-declared references and links; they do not establish legal support or UGLC qualification. Up to 20 outgoing references are displayed.
- openalex:w1517517048 · CITES
- openalex:w1933444487 · CITES
- openalex:w1935466508 · CITES
- openalex:w2024916097 · CITES
- openalex:w2037580869 · CITES
- openalex:w2057975177 · CITES
- openalex:w2068048966 · CITES
- openalex:w2074304698 · CITES
- openalex:w2078760864 · CITES
- openalex:w2090717848 · CITES
- openalex:w2103360140 · CITES
- openalex:w2112573173 · CITES
- openalex:w2138597772 · CITES
- openalex:w2144424358 · CITES
- openalex:w2146569181 · CITES
- openalex:w2149601054 · CITES
- openalex:w2155194464 · CITES
- openalex:w2261275821 · CITES
- openalex:w2283038830 · CITES
- openalex:w2333251385 · CITES
0 incoming references within the detected corpus
Documentary field provenance
Source-backed values and values with unresolved provenance are kept separately. Bibliographic provenance validates no legal claim.
- Title
- Documentary source reported
- Publication
- Documentary source reported
- Authors
- Documentary source reported
- Document type
- Documentary source reported
- Jurisdiction
- Not recorded
- Court
- Not recorded
- Issuing authority
- Not recorded
- Publisher
- Not recorded
- DOI
- Documentary source reported
- ISBN
- Not recorded
- Official identifier
- Not recorded
- Source URL
- Documentary source reported
- Source-reported status
- Not recorded
- Amendment / repeal
- Not recorded
Cite this reference
Jose L. Zavaleta‐Ruiz; Stefania Fatone; Matthew J. Major; Pankaj Pankaj. Mechanical Stimulation in the Residual Femur During Gait in Transfemoral Prosthesis Users Provides a Potential Reason for Bone Mineral Density Loss. 2025. https://doi.org/10.1002/cnm.70103
JSON · CSL-JSON · BibTeX · RIS · CSV · JSON-LD ·
APA, Chicago, ISO 690: bibliographic formats using available fields. OSCOLA / Bluebook: structured data only; full legal citation compliance is not claimed without verification of required elements.
- APA
- Jose L. Zavaleta‐Ruiz; Stefania Fatone; Matthew J. Major; Pankaj Pankaj. (2025). Mechanical Stimulation in the Residual Femur During Gait in Transfemoral Prosthesis Users Provides a Potential Reason for Bone Mineral Density Loss. https://doi.org/10.1002/cnm.70103
- Chicago
- Jose L. Zavaleta‐Ruiz; Stefania Fatone; Matthew J. Major; Pankaj Pankaj. Mechanical Stimulation in the Residual Femur During Gait in Transfemoral Prosthesis Users Provides a Potential Reason for Bone Mineral Density Loss. 2025. https://doi.org/10.1002/cnm.70103
- ISO 690
- Jose L. Zavaleta‐Ruiz; Stefania Fatone; Matthew J. Major; Pankaj Pankaj. Mechanical Stimulation in the Residual Femur During Gait in Transfemoral Prosthesis Users Provides a Potential Reason for Bone Mineral Density Loss. 2025. https://doi.org/10.1002/cnm.70103
UDTR Global Rights of Nature Legal Library. Mechanical Stimulation in the Residual Femur During Gait in Transfemoral Prosthesis Users Provides a Potential Reason for Bone Mineral Density Loss. Documentary record: https://www.declarationuniverselledesdroitsdelarbre.org/global-rights-of-nature-radar/reference/r-086453c042df8df4c8d9e90360a6be08/ · Last HTTP verification: not performed
Field provenance and record version
Version a7354e972f95612e · udtr-reference-1.1.2
- Title
- OpenAlex · source · 2026-11-09T19:16:01.560938+00:00
- Authors
- OpenAlex · source · 2026-11-09T19:16:01.560938+00:00
- Year
- OpenAlex · source · 2026-11-09T19:16:01.560938+00:00
- Identifiers
- OpenAlex · source · 2026-11-09T19:16:01.560938+00:00
- Source URL
- OpenAlex · source · 2026-11-09T19:16:01.560938+00:00
- Source-reported author ORCID
- OpenAlex · source · 2026-11-09T19:16:01.560938+00:00
OpenAlex · source · 2026-11-09T19:16:01.560938+00:00
History tracks record metadata and does not certify the state of the law.
cf7a37c4107bbc9f · 2026-11-09T19:16:01.560938+00:00
7981ee160b39f7ea · 2026-11-09T19:16:01.560938+00:00
58749180257e501d · 2026-11-09T19:16:01.560938+00:00
a7354e972f95612e · 2026-11-09T19:16:01.560938+00:00
Research dossiers and documentary relations
Source roles
Discovery source · https://doi.org/10.1002/cnm.70103
Discovery source · https://openalex.org/W4415013930
An authority link alone does not verify a legal claim. Abstracts and full texts remain subject to their source terms.
Documentary status
Relevance pending
Library
This identity is not yet included in the Legal Library.